| Basic Functions | Frequency | 0.00Hz-400.00Hz |
| Carrier Frequency | 2.0-16.0KHz |
| Frequency Setting Resolution | Analog setting: 0.1% of the highest frequency, Digital setting: 0.01Hz |
| Control Modes | V/F control, Open-loop vectro control |
| Speed Stability | ±0.5% |
| Overload Capacity | G-type machine: With reverse-time-limit overload protection, 115% for 6 minutes, 150% for 1 minute |
| V/F Curves | Three modes: Linear, Quadratic, 1.5th power, 1.2nd power, User-defined V/F curve, V/F Separation |
| Acceleration Curve | Linear mode |
| DC Braking | DC brake start frequency: 0.00% - upper limit frequency, Brake time: 0.0-60.0s; Brake current: 0.0-100% of motor's rated current. |
| Jog Control | Jog frequency range: 0.0Hz - maximum frequency, Jog acceleration/deceleration time: 0.1-999.9s |
| Simple PLC and Multi-segment Speed Running | Up to 7 segments of speed running |
| Build-in PID | Capable of implementing closed-loop control system for process control |
| Motor Parameter Identification | Static identification |
| Overvoltage, Overcurrent, Stalling, and Over-Excitation Control | Automatically limits current and voltage during operation, preventing frequent overcurrent, overvoltage, and trips |
| Torque Boost and Slip Compensation | Torque boost can be selected as automatic or manual, Slip compensation enhances low-speed loaded capacity and compensates for slip speed |
| Communication Function | Not available; SD320 has RS485 communication |
| Braking Function | Not available; SD320 has braking function |
| Customizable Functions | Oscillation Suppression | Enables oscillation suppression to eliminate oscillations and prevent overcurrent in the inverter |
| PID Control | Built-in PID controller for process control |
| Swing Frequency Function | Outputs frequency, oscillating up and down around the set frequency, suitable for industries like textiles and chemical fibers |
| Operating Functions | Upper and lower frequency setting, frequency hopping operation, reverse operation limitation, frequency increment and decrement control, fault auto-recovery operation, and more. |
| Constant Pressure Water Supply Function | Maintains constant water pressure and automatically sleeps and wakes up based on pressure |
|